Quellcodebibliothek Statistik Leitseite products/Sources/formale Sprachen/C/MariaDB/mysql-test/suite/rpl/r/   (MariaDB Server Version 8.1-8.4©)  Datei vom 1.9.2026 mit Größe 3 kB image not shown  

Quelle  rpl_known_bugs_detection.result   Sprache: Lisp

 

call mtr.add_suppression("Unsafe statement written to the binary log using statement format");
include/master-slave.inc
connection master;
CREATE TABLE t1 (
id bigint(20) unsigned NOT NULL auto_increment,
field_1 int(10) unsigned NOT NULL,
field_2 varchar(255) NOT NULL,
field_3 varchar(255) NOT NULL,
PRIMARY KEY (id),
UNIQUE KEY field_1 (field_1, field_2)
);
CREATE TABLE t2 (
field_a int(10) unsigned NOT NULL,
field_b varchar(255) NOT NULL,
field_c varchar(255) NOT NULL
);
INSERT INTO t2 (field_a, field_b, field_c) VALUES (1, 'a', '1a');
INSERT INTO t2 (field_a, field_b, field_c) VALUES (2, 'b', '2b');
INSERT INTO t2 (field_a, field_b, field_c) VALUES (3, 'c', '3c');
INSERT INTO t2 (field_a, field_b, field_c) VALUES (4, 'd', '4d');
INSERT INTO t2 (field_a, field_b, field_c) VALUES (5, 'e', '5e');
connection slave;
connection master;
INSERT INTO t1 (field_1, field_2, field_3)
SELECT t2.field_a, t2.field_b, t2.field_c
FROM t2
ON DUPLICATE KEY UPDATE
t1.field_3 = t2.field_c;
Warnings:
Note 1592 Unsafe statement written to the binary log using statement format since BINLOG_FORMAT = STATEMENT. INSERT... SELECT... ON DUPLICATE KEY UPDATE is unsafe because the order in which rows are retrieved by the SELECT determines which (if any) rows are updated. This order cannot be predicted and may differ on master and the slave.
Note 1592 Unsafe statement written to the binary log using statement format since BINLOG_FORMAT = STATEMENT. Statements writing to a table with an auto-increment column after selecting from another table are unsafe because the order in which rows are retrieved determines what (if any) rows will be written. This order cannot be predicted and may differ on master and the slave.
INSERT INTO t2 (field_a, field_b, field_c) VALUES (6, 'f', '6f');
INSERT INTO t1 (field_1, field_2, field_3)
SELECT t2.field_a, t2.field_b, t2.field_c
FROM t2
ON DUPLICATE KEY UPDATE
t1.field_3 = t2.field_c;
Warnings:
Note 1592 Unsafe statement written to the binary log using statement format since BINLOG_FORMAT = STATEMENT. INSERT... SELECT... ON DUPLICATE KEY UPDATE is unsafe because the order in which rows are retrieved by the SELECT determines which (if any) rows are updated. This order cannot be predicted and may differ on master and the slave.
Note 1592 Unsafe statement written to the binary log using statement format since BINLOG_FORMAT = STATEMENT. Statements writing to a table with an auto-increment column after selecting from another table are unsafe because the order in which rows are retrieved determines what (if any) rows will be written. This order cannot be predicted and may differ on master and the slave.
SELECT * FROM t1;
id field_1 field_2 field_3
1 1 a 1a
2 2 b 2b
3 3 c 3c
4 4 d 4d
5 5 e 5e
6 6 f 6f
connection slave;
include/wait_for_slave_sql_error.inc [errno=1105]
Last_SQL_Error = 'Error 'master may suffer from http://bugs.mysql.com/bug.php?id=24432 so slave stops; check error log on slave for more info' on query. Default database: 'test'. Query: 'INSERT INTO t1 (field_1, field_2, field_3)
SELECT t2.field_a, t2.field_b, t2.field_c
FROM t2
ON DUPLICATE KEY UPDATE
t1.field_3 = t2.field_c''
SELECT * FROM t1;
id field_1 field_2 field_3
connection master;
drop table t1, t2;
connection slave;
drop table t1, t2;
include/stop_slave_io.inc
RESET SLAVE;
include/rpl_end.inc

Messung V0.5 in Prozent
C=75 H=93 G=84

¤ Dauer der Verarbeitung: 0.4 Sekunden  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

PVS Prover

Isabelle Prover

NIST Cobol Testsuite

Cephes Mathematical Library

Vienna Development Method

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.