Quellcodebibliothek Statistik Leitseite products/Sources/formale Sprachen/C/MariaDB/mysql-test/suite/funcs_1/storedproc/   (MariaDB Server Version 8.1-8.4©)  Datei vom 1.9.2026 mit Größe 1 kB image not shown  

Quelle  param_check.inc   Sprache: Delphi

 

# suite/funcs_1/storedproc/param_check.inc
#
# Auxiliary routine to be sourced by
# suite/funcs_1/t/storedproc.test
#
# Purpose:
#    The assignment of float values to objects of type DECIMAL causes
#    conversions and in some cases an adjustment of the value to
#    a border of the value range.
#    Try to reveal that function and procedure parameters get a similar
#    mangling of the value like columns.
#    
# Variables to be set before sourcing this routine
#    $test_value  - value to be checked
#
# Created:
# 2008-08-27 mleich
#
# Modified:
# 2008-11-17 pcrews
# added --disable / --enable_warning statements to minimize differences
# between platforms (Bug#40177 Test funcs_1.storedproc failing on Pushbuild)
#
# TODO:  (After 5.1 GA)
# 1)  Examine reordering statements in this file to minimize the number of
#     --disable / --enable_warning statements.  Unsure if performance gains
#     warrant the working time
# 2)  We could probably add a comparison of the # of warnings before the
#     assignment of @v1_proc and @v1_func to the # of warnings after assignment
#     The difference of these values should be zero
# Refer to Bug#40177 - http://bugs.mysql.com/bug.php?id=40177 for notes as well
 
eval UPDATE t1_aux SET f1 = NULL;
# Enforce that all user variables have the same data type and initial value.
--disable_cursor_protocol
SELECT f1,f1,f1,f1 INTO @v1_tab,@v1_proc,@v2_proc,@v1_func FROM t1_aux;
--enable_cursor_protocol

--disable_warnings
eval UPDATE t1_aux SET f1 = $test_value;
--enable_warnings
--disable_cursor_protocol
SELECT f1 INTO @v1_tab FROM t1_aux;
--enable_cursor_protocol
--disable_warnings
eval CALL sproc_1($test_value, @v1_proc);
eval SET @v1_func = func_1($test_value);
--enable_warnings

if (`SELECT @v1_tab <> @v1_proc OR @v1_tab <> @v2_proc OR @v1_tab <> @v1_func`)
{
   --echo Error: @v1_tab, @v1_proc, @v2_proc, @v1_func are not all equal
   SELECT @v1_tab, @v1_proc, @v2_proc, @v1_func;
}

Messung V0.5 in Prozent
C=82 H=98 G=90

¤ Dauer der Verarbeitung: 0.12 Sekunden  (vorverarbeitet am  2026-10-10) ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

PVS Prover

Isabelle Prover

NIST Cobol Testsuite

Cephes Mathematical Library

Vienna Development Method

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.