OMAP3's Synchronous Serial Interface (SSI) controller implements a
legacy variant of MIPI's High Speed Synchronous Serial Interface (HSI),
while the controller found inside OMAP4 is supposed to be fully compliant
with the HSI standard.
Required properties:
- compatible: Should include "ti,omap3-ssi" or "ti,omap4-hsi"
- reg-names: Contains the values "sys" and "gdd" (in this order).
- reg: Contains a matching register specifier for each entry
in reg-names.
- interrupt-names: Contains the value "gdd_mpu".
- interrupts: Contains matching interrupt information for each entry
in interrupt-names.
- ranges: Represents the bus address mapping between the main
controller node and the child nodes below.
- clock-names: Must include the following entries:
"ssi_ssr_fck": The OMAP clock of that name
"ssi_sst_fck": The OMAP clock of that name
"ssi_ick": The OMAP clock of that name
- clocks: Contains a matching clock specifier for each entry in
clock-names.
- #address-cells: Should be set to <1>
- #size-cells: Should be set to <1>
Each port is represented as a sub-node of the ti,omap3-ssi device.
Required Port sub-node properties:
- compatible: Should be set to the following value
ti,omap3-ssi-port (applicable to OMAP34xx devices)
ti,omap4-hsi-port (applicable to OMAP44xx devices)
- reg-names: Contains the values "tx" and "rx" (in this order).
- reg: Contains a matching register specifier for each entry
in reg-names.
- interrupts: Should contain interrupt specifiers for mpu interrupts
0 and 1 (in this order).
- ti,ssi-cawake-gpio: Defines which GPIO pin is used to signify CAWAKE
events for the port. This is an optional board-specific
property. If it's missing the port will not be
enabled.
Optional properties:
- ti,hwmods: Shall contain TI interconnect module name if needed
by the SoC