**************************************************************** * * COMMENT SECTION * * DATE 1994/7/25 EMBEDDED COBOL LANGUAGE * NIST SQL VALIDATION TEST SUITE V6.0 * DISCLAIMER: * This program was written by employees of NIST to test SQL * implementations for conformance to the SQL standards. * NIST assumes no responsibility for any party's use of * this program. * * DML128.PCO * WRITTEN BY: David W. Flater * TRANSLATED AUTOMATICALLY FROM EMBEDDED C BY CHRIS SCHANZLE * * This routine tests FIPS feature 12 (GET DIAGNOSTICS). * * REFERENCES * FIPS PUB 127-2 14.1 Transitional SQL * ANSI SQL-1992 * ****************************************************************
MOVE"FLATER "TO uid CALL"AUTHID"USING uid MOVE"not logged in, not"TO uidx EXECSQLSELECT USER INTO :uidx FROM HU.ECCO END-EXEC MOVE SQLCODE TO SQL-COD EXECSQL ROLLBACK WORK END-EXEC MOVE SQLCODE TO SQL-COD if (uid NOT = uidx) then DISPLAY"ERROR: User ", uid " expected. User ", uidx "
- " connected" STOPRUN END-IF MOVE 0 TO errcnt
DISPLAY "SQL Test Suite, V6.0, Embedded COBOL, dml128.pco" DISPLAY "59-byte ID" DISPLAY"TEd Version #" *date_time print ACCEPT TO-DAY FROMDATE ACCEPT THE-TIME FROMTIME DISPLAY"Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
******************** BEGIN TEST0674 ******************* MOVE 1 TO flag
DISPLAY"INSERT INTO HU.STAFF VALUES (" DISPLAY" 'E1', 'Bart', 10, 'Annapolis');" EXECSQLINSERTINTO HU.STAFF VALUES ( 'E1', 'Bart', 10, 'Annapolis') END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"SQLCODE should be < 0; its value is ", SQL-COD if (SQLCODE NOT < 0) then MOVE 0 TO flag END-IF DISPLAY"SQLSTATE should be 23000; its value is ", SQLSTATE PERFORM NOSUBCLASS THRU EXIT-NOSUBCLASS if (NORMSQ NOT = "23000") then MOVE 0 TO flag END-IF if (NORMSQ = "23000"AND NORMSQ NOT = SQLSTATE) then DISPLAY"Valid implementation-defined SQLSTATE accepted." END-IF DISPLAY" "
MOVE"xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx" TO svrnam MOVE"xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx" TO xnnam MOVE"xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx" TO ctcat MOVE"xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx" TO ctnam MOVE"xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx" TO catnam DISPLAY"GET DIAGNOSTICS EXCEPTION 1" DISPLAY" :svrnam = SERVER_NAME, :xnnam =
- " CONNECTION_NAME," DISPLAY" :ctcat = CONSTRAINT_CATALOG, :ctnam =
- " CONSTRAINT_NAME," DISPLAY" :catnam = CATALOG_NAME;" EXECSQL GET DIAGNOSTICS EXCEPTION 1
:svrnam = SERVER_NAME, :xnnam = CONNECTION_NAME,
:ctcat = CONSTRAINT_CATALOG, :ctnam = CONSTRAINT_NAME,
:catnam = CATALOG_NAME END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"SQLCODE should be >= 0; its value is ", SQL-COD if (SQLCODE < 0) then MOVE 0 TO flag END-IF DISPLAY"SQLSTATE should be 00000 or 01004; its value is ",
SQLSTATE PERFORM NOSUBCLASS THRU EXIT-NOSUBCLASS if (NORMSQ NOT = "00000"AND NORMSQ NOT = "01004") then MOVE 0 TO flag END-IF if (NORMSQ = "00000"AND NORMSQ NOT = SQLSTATE) then DISPLAY"Valid implementation-defined SQLSTATE accepted." END-IF DISPLAY"svrnam should be blank or set to a value; its
- " value is ", svrnam DISPLAY"xnnam should be blank or set to a value; its value
- " is ", xnnam DISPLAY"ctcat should be blank or set to a value; its value
- " is ", ctcat DISPLAY"ctnam should be blank or set to a value; its value
- " is ", ctnam DISPLAY"catnam should be blank or set to a value; its
- " value is ", catnam if (svrnam = "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx") then MOVE 0 TO flag END-IF if (xnnam = "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx") then MOVE 0 TO flag END-IF if (ctcat = "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx") then MOVE 0 TO flag END-IF if (ctnam = "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx") then MOVE 0 TO flag END-IF if (catnam = "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx") then MOVE 0 TO flag END-IF
DISPLAY"ROLLBACK WORK;" EXECSQL ROLLBACK WORK END-EXEC MOVE SQLCODE TO SQL-COD
PERFORM CHCKOK DISPLAY" "
if ( flag = 1 ) then DISPLAY" *** pass *** " EXECSQLINSERTINTO HU.TESTREPORT
VALUES('0674','pass','PCO') END-EXEC MOVE SQLCODE TO SQL-COD else DISPLAY" dml128.pco *** fail *** " EXECSQLINSERTINTO HU.TESTREPORT
VALUES('0674','fail','PCO') END-EXEC MOVE SQLCODE TO SQL-COD COMPUTE errcnt = errcnt + 1 END-IF
EXECSQL COMMIT WORK END-EXEC MOVE SQLCODE TO SQL-COD ******************** END TEST0674 ******************** ******************** BEGIN TEST0675 ******************* MOVE 1 TO flag
MOVE 0 TO int2 DISPLAY"int2 = 0" DISPLAY"SELECT TOO_LITTLE / :int2, TOO_LATE" DISPLAY" INTO :int1, :svrnam FROM DOUBLE_TROUBLE;" EXECSQLSELECT TOO_LITTLE / :int2, TOO_LATE INTO :int1, :svrnam FROM DOUBLE_TROUBLE END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"SQLCODE is ", SQL-COD DISPLAY"SQLSTATE is ", SQLSTATE
MOVE"x"TO yorn DISPLAY"GET DIAGNOSTICS :yorn = MORE;" EXECSQL GET DIAGNOSTICS :yorn = MORE END-EXEC MOVE SQLCODE TO SQL-COD PERFORM CHCKOK DISPLAY"yorn should be Y; its value is ", yorn if (yorn = "N") then DISPLAY"Nogo: implementation might only catch one
- " error." MOVE 2 TO flag END-IF if (yorn NOT = "Y"AND yorn NOT = "N") then MOVE 0 TO flag END-IF
DISPLAY"ROLLBACK WORK;" EXECSQL ROLLBACK WORK END-EXEC MOVE SQLCODE TO SQL-COD PERFORM CHCKOK DISPLAY" "
DISPLAY"DROP TABLE DOUBLE_TROUBLE CASCADE;" EXECSQL DROP TABLE DOUBLE_TROUBLE CASCADE END-EXEC MOVE SQLCODE TO SQL-COD PERFORM CHCKOK DISPLAY" "
DISPLAY"COMMIT WORK;" EXECSQL COMMIT WORK END-EXEC MOVE SQLCODE TO SQL-COD PERFORM CHCKOK DISPLAY" "
if (flag = 2) then DISPLAY" *** nogo *** " EXECSQLINSERTINTO HU.TESTREPORT
VALUES('0675','nogo','PCO') END-EXEC MOVE SQLCODE TO SQL-COD GOTO P199 END-IF if ( flag = 1 ) then DISPLAY" *** pass *** " EXECSQLINSERTINTO HU.TESTREPORT
VALUES('0675','pass','PCO') END-EXEC MOVE SQLCODE TO SQL-COD else DISPLAY" dml128.pco *** fail *** " EXECSQLINSERTINTO HU.TESTREPORT
VALUES('0675','fail','PCO') END-EXEC MOVE SQLCODE TO SQL-COD COMPUTE errcnt = errcnt + 1 END-IF
.
P199. DISPLAY"==============================================="
EXECSQL COMMIT WORK END-EXEC MOVE SQLCODE TO SQL-COD ******************** END TEST0675 ******************** **** TESTER MAY CHOOSE TO INSERT CODE FOR errcnt > 0 STOPRUN.
* **** Procedures for PERFORM statements
*Test SQLCODE and SQLSTATE for normal completion.
CHCKOK. DISPLAY"SQLCODE should be 0; its value is ", SQL-COD DISPLAY"SQLSTATE should be 00000; its value is ", SQLSTATE PERFORM NOSUBCLASS THRU EXIT-NOSUBCLASS if (SQLCODE NOT = 0 OR NORMSQ NOT = "00000") then MOVE 0 TO flag END-IF if (NORMSQ = "00000"AND NORMSQ NOT = SQLSTATE) then DISPLAY"Valid implementation-defined SQLSTATE accepted." END-IF
.
NOSUBCLASS.
*This routine replaces valid implementation-defined *subclasses with 000. This replacement equates valid *implementation-defined subclasses with the 000 value *expected by the test case; otherwise the test will fail. *After calling NOSUBCLASS, NORMSQ will be tested * SQLSTATE will be printed.
MOVE SQLSTATE TO NORMSQ
MOVE 3 TO norm1 *subclass begins in position 3 of char array NORMSQ *valid subclass begins with 5-9, I-Z, end of ALPNUM table PERFORMVARYING norm2 FROM 14 BY 1 UNTIL norm2 > 36 if (NORMSQX(norm1) = ALPNUM(norm2)) then MOVE"0"TO NORMSQX(norm1) END-IF END-PERFORM
*Quit if NORMSQ is unchanged. Subclass is not impl.-def. *Changed NORMSQ means implementation-defined subclass, *so proceed to zero it out, if valid (0-9,A-Z) if (NORMSQ = SQLSTATE) then GOTO EXIT-NOSUBCLASS END-IF
MOVE 4 TO norm1 *examining position 4 of char array NORMSQ *valid characters are 0-9, A-Z PERFORMVARYING norm2 FROM 1 BY 1 UNTIL norm2 > 36 if (NORMSQX(norm1) = ALPNUM(norm2)) then MOVE"0"TO NORMSQX(norm1) END-IF END-PERFORM
MOVE 5 TO norm1 *valid characters are 0-9, A-Z *examining position 5 of char array NORMSQ PERFORMVARYING norm2 FROM 1 BY 1 UNTIL norm2 > 36 if (NORMSQX(norm1) = ALPNUM(norm2)) then MOVE"0"TO NORMSQX(norm1) END-IF END-PERFORM
*implementation-defined subclasses are allowed for warnings *(class = 01). These equate to successful completion *SQLSTATE values of 00000. *Reference SQL-92 4.28 SQL-transactions, paragraph 2
if (NORMSQX(1) = "0"AND NORMSQX(2) = "1") then MOVE"0"TO NORMSQX(2) END-IF
.
EXIT-NOSUBCLASS. EXIT.
¤ Dauer der Verarbeitung: 0.13 Sekunden
(vorverarbeitet)
¤
Die Informationen auf dieser Webseite wurden
nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit,
noch Qualität der bereit gestellten Informationen zugesichert.
Bemerkung:
Die farbliche Syntaxdarstellung ist noch experimentell.