/* Wait until module enters enabled state */ for (i = 0; i < MAX_MODULE_ENABLE_WAIT; i++) { if ((ti_clk_ll_ops->clk_readl(reg) & mask) == ena) break;
udelay(1);
}
if (i < MAX_MODULE_ENABLE_WAIT)
pr_debug("omap clock: module associated with clock %s ready after %d loops\n",
name, i); else
pr_err("omap clock: module associated with clock %s didn't enable in %d tries\n",
name, MAX_MODULE_ENABLE_WAIT);
/* Not all modules have multiple clocks that their IDLEST depends on */ if (clk->ops->find_companion) {
clk->ops->find_companion(clk, &companion_reg, &other_bit); if (!(ti_clk_ll_ops->clk_readl(&companion_reg) &
(1 << other_bit))) return;
}
clk->ops->find_idlest(clk, &idlest_reg, &idlest_bit, &idlest_val);
r = ti_clk_ll_ops->cm_split_idlest_reg(&idlest_reg, &prcm_mod,
&idlest_reg_id); if (r) { /* IDLEST register not in the CM module */
_wait_idlest_generic(clk, &idlest_reg, (1 << idlest_bit),
idlest_val, clk_hw_get_name(&clk->hw));
} else {
ti_clk_ll_ops->cm_wait_module_ready(0, prcm_mod, idlest_reg_id,
idlest_bit);
}
}
if (clkdm_control && clk->clkdm) {
ret = ti_clk_ll_ops->clkdm_clk_enable(clk->clkdm, hw->clk); if (ret) {
WARN(1, "%s: could not enable %s's clockdomain %s: %d\n",
__func__, clk_hw_get_name(hw),
clk->clkdm_name, ret); return ret;
}
}
/* FIXME should not have INVERT_ENABLE bit here */
v = ti_clk_ll_ops->clk_readl(&clk->enable_reg); if (clk->flags & INVERT_ENABLE)
v &= ~(1 << clk->enable_bit); else
v |= (1 << clk->enable_bit);
ti_clk_ll_ops->clk_writel(v, &clk->enable_reg);
v = ti_clk_ll_ops->clk_readl(&clk->enable_reg); /* OCP barrier */
if (clk->ops && clk->ops->find_idlest)
_omap2_module_wait_ready(clk);
v = ti_clk_ll_ops->clk_readl(&clk->enable_reg); if (clk->flags & INVERT_ENABLE)
v |= (1 << clk->enable_bit); else
v &= ~(1 << clk->enable_bit);
ti_clk_ll_ops->clk_writel(v, &clk->enable_reg); /* No OCP barrier needed here since it is a disable operation */
if (!(ti_clk_get_features()->flags & TI_CLK_DISABLE_CLKDM_CONTROL) &&
clk->clkdm)
ti_clk_ll_ops->clkdm_clk_disable(clk->clkdm, hw->clk);
}