Quelle  omap4-cpu-thermal.dtsi   Sprache: unbekannt

 
// SPDX-License-Identifier: GPL-2.0-only
/*
 * Device Tree Source for OMAP4/5 SoC CPU thermal
 *
 * Copyright (C) 2013 Texas Instruments Incorporated - https://www.ti.com/
 * Contact: Eduardo Valentin <eduardo.valentin@ti.com>
 */

#include <dt-bindings/thermal/thermal.h>

cpu_thermal: cpu_thermal {
 polling-delay-passive = <250>; /* milliseconds */
 polling-delay = <1000>; /* milliseconds */

 /*
  * See 44xx files for single sensor addressing, omap5 and dra7 need
  * also sensor ID for addressing.
  */
 thermal-sensors = <&bandgap     0>;

 cpu_trips: trips {
  cpu_alert0: cpu_alert {
   temperature = <100000>; /* millicelsius */
   hysteresis = <2000>; /* millicelsius */
   type = "passive";
  };
  cpu_crit: cpu_crit {
   temperature = <125000>; /* millicelsius */
   hysteresis = <2000>; /* millicelsius */
   type = "critical";
  };
 };

 cpu_cooling_maps: cooling-maps {
  map0 {
   trip = <&cpu_alert0>;
   cooling-device =
    <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
  };
 };
};