Quellcodebibliothek Statistik Leitseite products/Sources/formale Sprachen/C/Linux/tools/perf/scripts/python/     Datei vom 24.10.2025 mit Größe 4 kB image not shown  

Quelle  powerpc-hcalls.py   Sprache: Python

 

# SPDX-License-Identifier: GPL-2.0+
#
# Copyright (C) 2018 Ravi Bangoria, IBM Corporation
#
# Hypervisor call statisics

from __future__ import print_function

import os
import sys

sys.path.append(os.environ['PERF_EXEC_PATH'] + \
 '/scripts/python/Perf-Trace-Util/lib/Perf/Trace')

from perf_trace_context import *
from Core import *
from Util import *

# output: {
# opcode: {
# 'min': minimum time nsec
# 'max': maximum time nsec
# 'time': average time nsec
# 'cnt': counter
# } ...
# }
output = {}

# d_enter: {
# cpu: {
# opcode: nsec
# } ...
# }
d_enter = {}

hcall_table = {
 4: 'H_REMOVE',
 8: 'H_ENTER',
 12: 'H_READ',
 16: 'H_CLEAR_MOD',
 20: 'H_CLEAR_REF',
 24: 'H_PROTECT',
 28: 'H_GET_TCE',
 32: 'H_PUT_TCE',
 36: 'H_SET_SPRG0',
 40: 'H_SET_DABR',
 44: 'H_PAGE_INIT',
 48: 'H_SET_ASR',
 52: 'H_ASR_ON',
 56: 'H_ASR_OFF',
 60: 'H_LOGICAL_CI_LOAD',
 64: 'H_LOGICAL_CI_STORE',
 68: 'H_LOGICAL_CACHE_LOAD',
 72: 'H_LOGICAL_CACHE_STORE',
 76: 'H_LOGICAL_ICBI',
 80: 'H_LOGICAL_DCBF',
 84: 'H_GET_TERM_CHAR',
 88: 'H_PUT_TERM_CHAR',
 92: 'H_REAL_TO_LOGICAL',
 96: 'H_HYPERVISOR_DATA',
 100: 'H_EOI',
 104: 'H_CPPR',
 108: 'H_IPI',
 112: 'H_IPOLL',
 116: 'H_XIRR',
 120: 'H_MIGRATE_DMA',
 124: 'H_PERFMON',
 220: 'H_REGISTER_VPA',
 224: 'H_CEDE',
 228: 'H_CONFER',
 232: 'H_PROD',
 236: 'H_GET_PPP',
 240: 'H_SET_PPP',
 244: 'H_PURR',
 248: 'H_PIC',
 252: 'H_REG_CRQ',
 256: 'H_FREE_CRQ',
 260: 'H_VIO_SIGNAL',
 264: 'H_SEND_CRQ',
 272: 'H_COPY_RDMA',
 276: 'H_REGISTER_LOGICAL_LAN',
 280: 'H_FREE_LOGICAL_LAN',
 284: 'H_ADD_LOGICAL_LAN_BUFFER',
 288: 'H_SEND_LOGICAL_LAN',
 292: 'H_BULK_REMOVE',
 304: 'H_MULTICAST_CTRL',
 308: 'H_SET_XDABR',
 312: 'H_STUFF_TCE',
 316: 'H_PUT_TCE_INDIRECT',
 332: 'H_CHANGE_LOGICAL_LAN_MAC',
 336: 'H_VTERM_PARTNER_INFO',
 340: 'H_REGISTER_VTERM',
 344: 'H_FREE_VTERM',
 348: 'H_RESET_EVENTS',
 352: 'H_ALLOC_RESOURCE',
 356: 'H_FREE_RESOURCE',
 360: 'H_MODIFY_QP',
 364: 'H_QUERY_QP',
 368: 'H_REREGISTER_PMR',
 372: 'H_REGISTER_SMR',
 376: 'H_QUERY_MR',
 380: 'H_QUERY_MW',
 384: 'H_QUERY_HCA',
 388: 'H_QUERY_PORT',
 392: 'H_MODIFY_PORT',
 396: 'H_DEFINE_AQP1',
 400: 'H_GET_TRACE_BUFFER',
 404: 'H_DEFINE_AQP0',
 408: 'H_RESIZE_MR',
 412: 'H_ATTACH_MCQP',
 416: 'H_DETACH_MCQP',
 420: 'H_CREATE_RPT',
 424: 'H_REMOVE_RPT',
 428: 'H_REGISTER_RPAGES',
 432: 'H_DISABLE_AND_GETC',
 436: 'H_ERROR_DATA',
 440: 'H_GET_HCA_INFO',
 444: 'H_GET_PERF_COUNT',
 448: 'H_MANAGE_TRACE',
 468: 'H_FREE_LOGICAL_LAN_BUFFER',
 472: 'H_POLL_PENDING',
 484: 'H_QUERY_INT_STATE',
 580: 'H_ILLAN_ATTRIBUTES',
 592: 'H_MODIFY_HEA_QP',
 596: 'H_QUERY_HEA_QP',
 600: 'H_QUERY_HEA',
 604: 'H_QUERY_HEA_PORT',
 608: 'H_MODIFY_HEA_PORT',
 612: 'H_REG_BCMC',
 616: 'H_DEREG_BCMC',
 620: 'H_REGISTER_HEA_RPAGES',
 624: 'H_DISABLE_AND_GET_HEA',
 628: 'H_GET_HEA_INFO',
 632: 'H_ALLOC_HEA_RESOURCE',
 644: 'H_ADD_CONN',
 648: 'H_DEL_CONN',
 664: 'H_JOIN',
 676: 'H_VASI_STATE',
 688: 'H_ENABLE_CRQ',
 696: 'H_GET_EM_PARMS',
 720: 'H_SET_MPP',
 724: 'H_GET_MPP',
 748: 'H_HOME_NODE_ASSOCIATIVITY',
 756: 'H_BEST_ENERGY',
 764: 'H_XIRR_X',
 768: 'H_RANDOM',
 772: 'H_COP',
 788: 'H_GET_MPP_X',
 796: 'H_SET_MODE',
 61440: 'H_RTAS',
}

def hcall_table_lookup(opcode):
 if (opcode in hcall_table):
  return hcall_table[opcode]
 else:
  return opcode

print_ptrn = '%-28s%10s%10s%10s%10s'

def trace_end():
 print(print_ptrn % ('hcall', 'count', 'min(ns)', 'max(ns)', 'avg(ns)'))
 print('-' * 68)
 for opcode in output:
  h_name = hcall_table_lookup(opcode)
  time = output[opcode]['time']
  cnt = output[opcode]['cnt']
  min_t = output[opcode]['min']
  max_t = output[opcode]['max']

  print(print_ptrn % (h_name, cnt, min_t, max_t, time//cnt))

def powerpc__hcall_exit(name, context, cpu, sec, nsec, pid, comm, callchain,
   opcode, retval):
 if (cpu in d_enter and opcode in d_enter[cpu]):
  diff = nsecs(sec, nsec) - d_enter[cpu][opcode]

  if (opcode in output):
   output[opcode]['time'] += diff
   output[opcode]['cnt'] += 1
   if (output[opcode]['min'] > diff):
    output[opcode]['min'] = diff
   if (output[opcode]['max'] < diff):
    output[opcode]['max'] = diff
  else:
   output[opcode] = {
    'time': diff,
    'cnt': 1,
    'min': diff,
    'max': diff,
   }

  del d_enter[cpu][opcode]
# else:
# print("Can't find matching hcall_enter event. Ignoring sample")

def powerpc__hcall_entry(event_name, context, cpu, sec, nsec, pid, comm,
    callchain, opcode):
  if (cpu in d_enter):
   d_enter[cpu][opcode] = nsecs(sec, nsec)
  else:
   d_enter[cpu] = {opcode: nsecs(sec, nsec)}

Messung
CHZG
889710095

¤ Dauer der Verarbeitung: 0.1 Sekunden  (vorverarbeitet am  2026-11-24) ¤

*© Formatika GbR, Deutschland